SWARMP vs. Unsafe — Understanding FISP Filing Conditions

Every façade report filed under NYC’s Façade Inspection Safety Program (FISP) places the building in one of three categories: Safe, SWARMP, or Unsafe. The category drives what the owner must do next, and how soon.

FISP is governed by Article 302 of Title 28 of the Administrative Code and the Department of Buildings’ rule at 1 RCNY §103-04. A Qualified Exterior Wall Inspector (QEWI) examines the exterior walls and appurtenances and classifies the building based on the worst condition found.

Safe

The rule defines a safe condition as one “not requiring repair or maintenance to sustain the structural integrity of the exterior of the building” that “will not become unsafe during the next five years.” If a building has no unsafe and no SWARMP conditions, it is classified as Safe for that filing cycle.

SWARMP — Safe With a Repair and Maintenance Program

A SWARMP condition is one that is “safe at the time of inspection, but requires repairs or maintenance during the next five years, but not less than one year, in order to prevent its deterioration into an unsafe condition.”

Unsafe

An unsafe condition is one “that is hazardous to persons or property.” Any condition reported as SWARMP in a previous report that has not been corrected at the time of the current inspection must also be reported as unsafe.

How conditions are determined

The QEWI designs an inspection program specific to the building, based on its construction, the age of its materials, its exposure, and its maintenance history. The rule requires physical (close-up) examinations from a scaffold or other observation platform at intervals of not more than 60 feet along each façade fronting a public right-of-way. The QEWI must also order any special or additional inspections and tests, including sounding procedures, needed to investigate and determine the causes of defects, and probes of cavity wall construction are required in the cycles the rule specifies. Drones, high-resolution photography, and other non-destructive methods do not replace the close-up inspection. Photographs and sketches document the location of every unsafe or SWARMP condition.

After an Unsafe filing

How SAS helps

Saghari Architectural Services’ QEWIs work with owners and managing agents to classify conditions accurately, to define a repair scope that addresses what is needed without unnecessary work, and to prepare the follow-up filing once repairs are complete.

This article is general information, not legal or engineering advice. Requirements are set by the Department of Buildings and may change; refer to the current text of 1 RCNY §103-04 and consult a QEWI about your building.